当前位置:首页 > 屋顶风冷空调(热泵)机屋顶风冷空调(热泵)机
|
屋顶风冷空调(热泵)机 |
|
|
屋顶式风冷空调(热泵)机组参数表
The Parameter List for Rooftop Air-cooling Air Conditioner (Heat Pump Unit)
型号Model
|
制冷量Refrigerating capacity(kw)
|
制热量Heating capacity(kw)
|
风量Amount of blast(m3/h)
|
型号Model
|
制冷量Refrigerating capacity(kw)
|
制热量Heating capacity(kw)
|
风量Amount of blast(m3/h)
|
kW
|
kW
|
m3/h
|
kW
|
kW
|
m3/h
|
WKH28
|
28.08
|
20.7
|
6000
|
WKH135
|
136.7
|
64
|
27000
|
WKR30
|
31.12
|
32.68
|
WKR150
|
152.7
|
160.4
|
WK30
|
---
|
WK150
|
---
|
WKD30
|
18
|
WKD150
|
64
|
WKH40
|
41.27
|
30.6
|
8500
|
WKH165
|
165.2
|
81
|
32000
|
WKR45
|
45.86
|
48.15
|
WKR180
|
184.1
|
193.3
|
WK45
|
-
|
WK180
|
-
|
WKD45
|
23.4
|
WKD180
|
81
|
WKH56
|
56.16
|
30
|
12000
|
WKH200
|
202.9
|
99
|
36000
|
WKR60
|
62.24
|
65.35
|
WKR225
|
226
|
237.3
|
WK60
|
-
|
WK225
|
-
|
WKD60
|
30
|
WKD225
|
99
|
WKH70
|
72.07
|
32.4
|
14000
|
WKH250
|
252
|
126
|
40000
|
WKR80
|
80.39
|
84.41
|
WKR275
|
275.5
|
289.3
|
WK80
|
-
|
WK275
|
-
|
WKD80
|
32.4
|
WKD275
|
126
|
WKH94
|
94.29
|
45
|
18000
|
WKH330
|
332
|
162
|
50000
|
WKR100
|
105.2
|
110.5
|
WKR360
|
363
|
381
|
WK100
|
-
|
WK360
|
-
|
WKD100
|
45
|
WKD360
|
162
|
WKH108
|
108.2
|
54
|
22000
|
WKH415
|
415
|
207
|
58000
|
WKR120
|
121.4
|
127.5
|
WKR460
|
462.4
|
485.5
|
WK120
|
-
|
WK460
|
-
|
WKD120
|
54
|
WKD460
|
207
|
注:
1.WKH机组制冷量标定工况:室内空气干/湿球温度为23℃/17℃,室外空气干/湿球温度为35℃/24℃。
2.其它机组制冷量标定工况:室内空气干/湿球温度为27℃/19℃,室外空气干/湿球温度35℃/24℃。
3.WKR机组制热量标定工况:室内空气干球温度21℃,室外环境干/湿球温度为7℃/6℃。
4.机组的标准型为电加热型。热水(60℃)加热型和蒸汽(0.2MPa)加热型为非标产品。
5.性能参数表中的送风量、机外余压和加湿量等参数,可以按用户要求另行设计。
Remarks:
1. The demarcated working order of the Refrigerating capacity for WKH units:
The dry / wet ball temperature of air inside the room is 23℃/17℃;
The dry / wet ball temperature of air outside the room is 35℃/24℃;
2. The demarcated working order of the refrigerating capacity for other units:
The dry / wet ball temperature of air inside the room is 27℃/19℃;
The dry / wet ball temperature of air outside the room is 35℃/24℃;
3. The demarcated working order of the heating capacity for WKH units:
The dry ball temperature of air inside the room is 21℃;
The dry / wet ball temperature of circumstances outside the room is 7℃/6℃;
4. The standard type of the unit is electrothermal type. Hot water(60℃) heating type and steam(0.2Mpa) heating type are nonstandard products.
5. The parameters of amount of blast, remnant pressure outside the machine and damping amount etc. in the performance reference list, which can be designed according to the requirements of the consumers.
|